SUPERVISION MODULE

The Supervision Module (TSPV) allows the management of the entire optical system.
Up to 9 fully equipped optical subracks (i.e. 144 remote units) can be monitored connecting a PC, either locally or remotely, to the Ethernet port.
The RS232 port is available for remote control via an external PSTN or wireless modem.
An embedded web server allows system control and management via a standard web browser.
Multiple optical systems in a Network can be managed via our OMC software.

Alarm notification can be forwarded from the Supervision Module via SNMP trap, SMS, e-mail or software configurable dry contacts connected to the BTS/Node B external alarms.

- Summary alarms
- Remote control and management via LAN or external dial-up modem
- High level alarm management via SNMP trap, SMS messages, or e-mail
- Summary dry contacts
- Different kinds of reports for alarm and system composition

Options:
Internal Wireless Modem (GSM850/900/1800/1900 or CDMA850/1900) with SMS capabilities for remote management
Battery pack with 15min autonomy  of the Supervision Module in case of black out

External alarm inputs   4 available
Dry contacts output   4 available
Local control interface   RJ45 Ethernet
Remote control interface   RJ45 Ethernet
Optional CDMA (850/1900) or
GSM (850/900/1800/1900) modem
Number of monitored subracks    1 + 8
Maximum number of
Remote Units supervised 
   144

 

IMAGES

Picture